REFRIGERATION AND DEEP-FREEZING – TWO TEMPERATURE RANGES
The technical advantages of COMBI Gabler containers:
- Refrigeration and deep-freezing in one
- Insulation 140 mm
- Increased usable space
- Reduced energy consumption
- Each unit area can have a separate setting
- Set up –connect power – select temperature range – the system is running
- Separate, easily accessible machine room
- Systems monitored remotely
- Error messages per room
- Temperature control and correction, initiation of defrosting etc. possible vie remote control
- Base in stainless steel with TRI sheet metal
- Can be placed on the floor or on a loading ramp by means of an exchange platform
- SUVA-compliant personal protection device per room
- Air-cooled condenser, designed for an ambient temperature of +37°C
- Semi-hermetic, performance-controlled refrigeration compressors
- Floor load capacity 1000 kp/m2
- On-site power connection
FIELDS OF APPLICATION
- Food
- Pharma
- Chemistry
- Gastro
- Catering
- Events/Open-air
COMBI REFRIGERATED/DEEP-FREEZE CONTAINER 10.10

- 3000
- 3000
- 2570
Masse = Innenmasse
KK/TC 10.10
Number of pallets | 6/6 |
Outer dimensions | 7560 x 2970 x 2900 |
Internal dimensions | 7.6 m2 / 7.6 m2 |
Connected load | 8 KW |
Max. operating current | 25A |
Voltage V/Hz/Ph | 400 / 50 / 3 |
Pre-fuse | 40A / FI |
Plug connection | CEE 32A |
Door dimensions | 2000 x 2000 / 900 x 2000 |
Container empty | 3720 kg |
KOMBI KÜHL-/TIEFKÜHLCONTAINER 15.10

- 2900
- 4215
- 2570
Masse = Innenmasse
KK/TC 15.10
Number of pallets | 9/6 |
Outer dimensions | 8700 x 2970 x 2900 |
Internal dimensions | 10.9 m2 / 7.25 m2 |
Connected load | 8 KW |
Max. operating current | 25A |
Voltage V/Hz/Ph | 400 / 50 / 3 |
Pre-fuse | 40A / FI |
Plug connection | CEE 32A |
Door dimensions | 2000 x 2000 / 900 x 2000 |
Container empty | 4310 kg |
KOMBI KÜHL-/TIEFKÜHLCONTAINER 15.15

- 4215
- 4215
- 2570
Masse = Innenmasse
KK/TC 15.15
Number of pallets | 9/9 |
Outer dimensions | 10100 x 2970 x 2900 |
Internal dimensions | 10.9 m2 / 10.9 m2 |
Connected load | 8 KW |
Max. operating current | 25A |
Voltage V/Hz/Ph | 400 / 50 / 3 |
Pre-fuse | 40A / FI |
Plug connection | CEE 32A |
Door dimensions | 2000 x 2000 / 900 x 2000 |
Container empty | 5040 kg |
KOMBI KÜHL-/TIEFKÜHLCONTAINER 20.15

- 4500
- 5430
- 2570
Masse = Innenmasse
KK/TC 20.15
Number of pallets | 14/9 |
Outer dimensions | 11600 x 2970 x 2900 |
Internal dimensions | 14.7 m² / 10.9 m² |
Connected load | 10 KW |
Max. operating current | 2x 20A |
Voltage V/Hz/Ph | 400 / 50 / 3 |
Pre-fuse | 2x 25A / FI |
Plug connection | 2x CEE 32A |
Door dimensions | 2000 x 2000 / 900 x 2000 |
Container empty | 6300 kg |
KOMBI KÜHL-/TIEFKÜHLCONTAINER 20.20

- 5715
- 5715
- 2570
Masse = Innenmasse
KK/TC 20.20
Number of pallets | 14/14 |
Outer dimensions | 13100 x 2970 x 2900 |
Internal dimensions | 14.7 m² / 14.7 m² |
Connected load | 12 KW |
Max. operating current | 2x 20A |
Voltage V/Hz/Ph | 400 / 50 / 3 |
Pre-fuse | 2x 25A / FI |
Plug connection | 2x CEE 32A |
Door dimensions | 2000 x 2000 / 900 x 2000 |
Container empty | 6656 kg |